 CDP68HC68S1
April 1994
Serial Multiplexed Bus Interface
Description
The CDP68HC6SS1 Serial Bus Interface Chip (SBlC) provides a means of interfacing in a Small Area Network configuration, various microcomputers (MCU's) containing serial ports. Such MCU's include the family of 68HC05 microcontrollers. The SBlC provides a connection from an MCU's Serial Communication Interface (asynchronous UART type interface) or Serial Peripheral Interface (synchronous) to a medium speed asynchronous two wire differential signal bus designed to minimize electromagnetic interference. This two wire bus forms the network bus to which all MCU's are connected (through SBI chips). See Figure 1. Each MCU operates independently and may be added or deleted from the bus with little or no impact on bus operation. Such a bus is ideal for inter-microcomputer communication in hazardous electrical environments such as automobiles, aircraft or industrial control systems. In addition to acting as bus arbitor and interface for microcomputer SCI port to differential bus communication, the CDP68HC68S1 contains all the circuitry required to convert and synchronize Non-Return-to-Zero (NRZ) 8-bit data received on the differential bus and clock the data into a microcomputer's SPl port. Likewise, data to be sent by a microcomputer's SPI port is converted to asynchronous format by appending start and stop bits before transmitting to other microcomputers. Refer to the data sheet for the CDP68HCO5C4 for additional information regarding CDP68HCO5 microcomputers and their Serial Communications and Serial Peripheral Interfaces. The CDP68HC68S1 is supplied in a 14 lead dual-in-line plastic package (E suffix), and in a 20 lead small outline plastic package (M suffix). Operating voltage ranges from 4V to 7V and operating temperature ranges from -40oC to +105oC.
Features
* Differential Bus for Minimal EMl * High Common Mode Noise Rejection * Ideal for Twisted Pair Wiring * Data Collision Detection * Bus Arbitration * Idle Detection * Programmable Clock Divider * Power-On Reset
Ordering Information
PART NUMBER CDP68HC68S1E CDP68HC68S1M TEMPERATURE RANGE -40oC to +105oC -40oC to +105oC PACKAGE 14 Lead PDIP 20 Lead SOIC (W)
Pinouts
CD68HC68S1 (PDIP) TOP VIEW
CLK 1 A2 B3 MODE 4 BUS+ 5 BUS- 6 VSS 7 14 VDD 13 CONTROL 12 IDLE 11 CS 10 SCK 9 REC 8 XMIT BUSCLK A B MODE NC NC BUS+ NC
CD68HC68S1 (SOIC) TOP VIEW
1 2 3 4 5 6 7 8 9 20 VDD 19 CONTROL 18 NC 17 IDLE 16 CS 15 SCK 14 NC 13 NC 12 REC 11 XMIT
VSS 10
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures. 407-727-9207 | Copyright (c) Intersil Corporation 1999
File Number
1918.3
6-84
CDP68HC68S1 Block Diagram
SCK TO FROM MCU XMIT REC CS MODE CLOCK DIVIDER WORD COUNTER AND CLOCK GENERATOR SPI/SCI CONVERSION IDLE DETECTION AND CONTROL ARBITRATION DETECTOR COLLISION DETECTOR BUS+ DIFFERNTIAL DRIVER/RECEIVER BUS-
CLK
A
B
TO OTHER SBI CHIPS CONTROL IDLE
6-85
Specifications CDP68HC68S1
Absolute Maximum Ratings
Supply Voltage (VDD) . . . . . . . . . . . . . . . . . . . . . . . . . -0.3V to +7.0V Input Voltage (VIN) . . . . . . . . . . . . . . . . . . VSS -0.3V to VDD+0.3VDC DC Input Current (IIN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10mA
Thermal Information
Thermal Resistance JA Plastic DIP Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100oC/W Plastic SOIC Package . . . . . . . . . . . . . . . . . . . . . . . . . . 120oC/W Storage Temperature Range (TSTG) . . . . . . . . . . . . -55oC to +125oC Lead Temperature (Soldering 10s) . . . . . . . . . . . . . . . . . . . . +265oC
CAUTION: Stresses above those listed in "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
Operating Conditions
Operating Temperature (TA) . . . . . . . . . . . . . . . . . . -40oC to +105oC DC Operating Voltage Range (VDD) . . . . . . . . . . . . . . . . +4V to +7V
DC Electrical Specifications
PARAMETERS SIGNAL I/O SECTION Output Voltage High Level Output Voltage Low Level Input Voltage Low Level Input Voltage High Level Output High Drive (Source) Current (REC Pin) Output High Drive (Source) Current (IDLE, Control Pins) Output Low Drive (Sink) Current (IDLE, Control, REC)
TA = -40oC to +105oC Unless Otherwise Noted. External Bias (VO) shall be 1.8V to 3.13V Unless Otherwise Noted. SYMBOLS TEST CONDITIONS MIN MAX UNITS
VOL VOH VIL VIH IOH IOH IOL
Open Circuit Open Circuit
VDD-0.05 0.7VDD
0.05 0.3VDD -
VDC VDC VDC VDC mA mA mA
VOH = 4.6V, VDD = 5V VOH = 4.6V, VDD = 5V VOH = 0.4V, VDD = 5V
-0.12 -0.04 0.36
DIFFERENTIAL TRANSCEIVER (SEE FIGURE 4) TRANSMITTER BUS+ IAOL IAOH BUSIBOL IBOH IAOL - IBOL Match Output Rise Time (BUS+) Output Fall Time (BUS-) Transition match (50% Point) RECEIVER Differential Sensitivity VIDH VIDL Hysteresis (Within VIDH , VIDL Limits) Propagation Delay Out of Range VH tP VAX VMIN Quiescent Device Current Clock Speed IDD fOP VO = 2.5V, RL = 120, VDD = 5V VO = 2.5V, RL = 120, VDD = 5V VO = 2.5V, RL = 120, VDD = 5V VIDH =120mV, VDD = 5V VDD = 5V VDD = 5V VDD = 0V, VO = 2.5V VDD = 5, RL = 120, CL = 25pF 20 20 3.8 -10 120 700 1.2 10 TBD (Note) mV mV mV ns V V A MHz IM tR tF tM VO = VDD/2, RL = 120 VO = VDD/2, RL = 120 VO = VDD/2, RL = 120 VO = VDD/2, RL = 120 VO = VDD/2, RL = 120, VDD = 5V 0.5V VDD = 5V, CL = 25pF VDD = 5V, CL = 25pF VDD = 5V, CL = 25pF 2.75 -1.0 -1.0 -50 1.0 -2.75 1.0 5 1.5 1.5 50 mA A mA A % s s ns
NOTE: Although 1MHz is generally used as an example throughout this datasheet, the maximum speed limit may be higher and depends upon user's noise tolerance requirements.
6-86
CDP68HC68S1
The Serial Bus IC offers the user three possible modes of operation as defined by Table 1 - SCl (Note 1), SPl, and Buffered SPl. Also included is a "three-state mode" entered by pulling the CS pin high while in the Buffered SPI mode. As the name implies, the SCl mode is used when communicating through the microcomputer's SCl port. In this mode, asynchronous NRZ data format (1 start bit, 8 data bits `least significant bit first', and 1 stop bit) and baud rate remain the same on each "side" of the SBlC, i.e. to and from the micro and to and from the differential network bus.
TABLE 1. MODE AND CHIP SELECT DEFINITION SBI CHIP MODE SCI SPI Buffered SPI Three-State (Note 2) NOTES: 1. SCI is the UART interface of a 68HCO5 MCU. The CDP68HC68S1 is compatable with most UART devices. 2. The three-state mode is only entered when using the Buffered SPI mode. In the three-state mode, only the XMIT, REC, and SCK pins are three-stated. The CONTROL and IDLE pins are always active. MODE PIN 1 1 0 0 CS PIN 1 0 0 1
bus "monitoring". The Serial BUS Interface chip handles bus arbitration, data collision detection, and provides short circuit protection. A 68HC0S MCU's SPI port may instead be used for bus communication. Two modes of SPl operation are available with the SBIC - one essentially places the 68HC05 microcomputer in the slave mode and the other allows the MCU to remain a master. In the normal SPl mode the SBIC acts as a master and supplies a data-synchronizing serial clock signal to the micro (which operates in the slave mode) for shifting data in or out of the micro's 8-bit SPl data register. Again, baud rates are the same on each side of the SBlC, however, the user must reverse the bit order of a byte transmitted or received via the SPI port due to the SPl's most significant bit first serial data nature. In addition, since the user microcomputer is operating in the slave mode it must signal the SBI chip (by pulling the CONTROL line low) to initiate a transmission. As in the SCl mode, during a transmission, the byte originally in the SPI data register is replaced by the byte reflected from the bus. Transmission and reception of data in the Buffered SPI mode allows the user to free the micro's SPl port by allowing fast data communication (1M bits/second) between the SPI port and SBlC. For instance, if the MCU is transmitting, the SBlC converts the data stream from the MCU's SPl port to a slower speed for transmission along the differential bus when the bus becomes idle. Data speed conversion is accomplished via a 2 byte (16-bit) data buffer register residing in the serial bus chip. In this mode the MCU operates as a master and provides the serial clock signal to the slave SBlC peripheral. After fast data has been sent to or received from the SBIC, the micro can pull the SBlC's CS pin high (placing the SBlC chip in the three-state mode) and then use the SPl port to access other SPl peripherals. All transfers between the user MCU and the SBlC in the Buffered SPI mode consist of 2 bytes, i.e. a message consists an even number of 8-bit transfers. A microcomputer wishing to transmit loads 2 bytes into the serial bus IC data register and then pulls the control pin low to initiate transmission. During transmission the 2 bytes placed into the buffer are replaced by the two reflected bytes received from the bus. After every 2 byte transmission the user micro should transfer the two reflected bytes out of the buffer and the next 2 bytes to be transmitted into the buffer.
TABLE 2. CLOCK PROGRAMMING
During data transmission, while a byte is being transmitted from the MCU through the SBl chip onto the differential bus, it is also reflected and simultaneously received back at the micro, (this is required for bus arbitration as described later).
DIFFERENTIAL BUS
SBI
SBI
SBI
SPI OR SCI
SPI OR SCI
SPI OR SCI
CLOCK INPUT DIVIDE FACTOR
A PIN 0 0 1 1
B PIN 0 1 0 1
MCU
MCU
MCU
/1 /2
FIGURE 1. POSSIBLE NETWORK CONFIGURATION-VARIOUS MICROCOMPUTERS USING SBI CHIPS TO COMMUNICATE ALONG DIFFERENTIAL BUS.
/4 / 10
In addition to performing a framing error check in the SCI mode, other advantages gained by using the SBlC (in any mode) include greater system EMl tolerance and automatic
6-87
CDP68HC68S1 Functional Pin Description
PIN NUMBER 1 SYMBOL CLK IN/OUT Input DESCRIPTION This is the clock input that shall be divided by the SBIC (as described in Table 2) and used as an internal synchronizing clock. The internal clock is then further divided by 128 to determine baud rate, i.e. 128 internal clock periods constitute 1-bit length. Programing inputs of the clock divider. These inputs are tied to +VDD or VSS depending upon speed of external clock source. (See Table 2) This input shall be used in conjunction with CS input to define the mode of operation (see Table 1). It may be permanently wired to +VDD or VSS or driven high or low by MCU I/O lines. This is the two wire differential bus I/O used to transmit and receive data to and from the differential bus. BUS+ is both responsive to, or driven positive by sourcing current from an externally established bias point. This sourcing current matches the BUS- I/Os sinking current. BUS- is both responsive to, or driven negative by sinking current from an externally established bias point. This sinking current matches the BUS+ I/Os sourcing current. Power and ground reference are supplied to the device via these pins. VDD is power and VSS is ground. In the SCI mode this data input shall come from the microcomputer standard NRZ asynchronous communications output port (68HC05 SCI port pin TxD). In the SPI modes, it shall come from the microcomputer's synchronous output port (68HC05 SPI port pin MOSl or MlSO). In the SCI mode this data output shall be fed into the microcomputer asynchronous communications input port (68HC05 SCI port pin RxD). In the SPI modes it shall be fed into the microcomputer's synchronous input port (6805 SP1 port pin MOSl or MISO). In the SCI mode, this I/O is not required. In both SPI modes this pin is connected to the 68HC05's SPI port SCK pin. In the normal SPl mode, the SBlC shall produce shift clock pulses via this pin for synchronously shifting data into and out of the microcomputer. In the Buffered SPl mode this pin is an input and the microcomputer shall generate the shift clock pulses. Figure 3 shows the relationship between the serial clock signal and other SBIC signals in the SPI mode. This input shall be used in conjunction with the mode input and shall be used as a chip select (see Table 1). It may be permanently wired to +VDD or VSS or driven high or low by MCU I/O lines. The microcomputer shall monitor this signal to determine the bus condition and also pull this line low to generate a break. The IDLE signal goes low when the bus is idle (after sensing an End of Message condition) and high when the bus is active. On reset, this pin is set to a logic zero. The microcomputer shall monitor this I/O pin in the SPl mode to handle transmission and reception of data. In the SCI and SPI modes, as an output, this pin will go low to indicate that a data byte is currently active on the bus. In the Buffered SPI mode the control pin indicates whether the user microcomputer has current access to the SBI chip's internal 2 byte buffer (signified by a logic high on the control pin). In both SPI modes the control pin is also effective as an input. In these modes the control pin is pulled low by the user microcomputer to initiate a transmit operation by the SBlC. The control pin is normally high when the bus is inactive. On reset, this pin is set to a logic high.
2, 3
A and B
Input
4
Mode
Input
5, 6
BUS+ and BUS-
Input/Output
14, 7
VDD and VSS XMIT
-
8
Input
9
REC
Output
10
SCK
Input/Output
11
CS
Input
12
IDLE
Input/Output
13
Control
Input/Output
All Intersil semiconductor products are manufactured, assembled and tested under ISO9000 quality systems certification.
Intersil products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design and/or specifications at any time without notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries.
For information regarding Intersil Corporation and its products, see web site http://www.intersil.com
6-88
CDP68HC68S1 Differential Transceiver Cell
The differential transceiver is a serial interface device which accepts digital signals and translates this information for transmitting on the two wire differential bus. The transmitter section (shown in Figure 4), when transmitting, provides matched constant current sources to the bus "+" and bus "-" I/O sourcing and sinking respectively. When transmitting, a logic zero at the "transmit data" input causes the bus "+" I/O to provide source current and the bus "-" I/O to provide a matched sink current. A logic one at the "transmit data" input causes the bus "+" and bus "-" I/Os to simultaneously provide a high impedance state. The bus depends on external resistor components for bias and termination. Recommended resistor sizes are shown in Figure 4.
SBI CHIP TRANSMIT BREAK DATA ----------------IA BUS+ + RECEIVE DATA 13K DIFF. BUS CL BUSIB OUTOF RANGE CL CL 13K APPROX. VOLTAGE 120 DIFF. BUS 2.2 LOGIC 0 LOGIC 0 2.5 BUSBUS+ LOGIC 1 VDD VDD 2.8 20mV MAX.
bus actually "floats" to a logic level one, but must be driven to a logic level zero. Logic 0-bits always dominate over logic 1bits on the bus. If two MCU's simultaneously transmit a zero and a one on the bus, the zero will override the one and the bus will merely appear to be transmitting a zero. The "marking" or idle signal on the bus is a logic one. If the bus is idle or if a micro is sending a logic one, then a one will appear on the bus. In addition to the transmission of data, the differential data transceiver accepts at its bus "+" and bus "-" I/Os, serial differential data which is translated into the standard digital logic levels. This reception of data also occurs while transmitting, thus reflecting the data seen on the bus back into the SBIC data register.
VDD = 5V 0.6V
-
FIGURE 4. DIFFERENTIAL DRIVER/RECEIVER
Typical voltage levels seen on BUS+ and BUSI/O pins for logic zero and logic 1-bits. Notice that the BUS- Pin is biased to actually sit a higher voltage potential than the BUS+. Values shown are for VDD = 5V FIGURE 5.
A zero transmitted on the bus will appear as a large voltage drop across the BUS+ and BUS- pins, i.e. BUS+ might typically sit at +2.8V and BUS- at +2.2V for a logic zero. For a logic level one, the SBlC actually three-states the BUS+ and BUS- pins and relies on external resistors to bias the bus lines. The lines are both biased to sit at approximately 2.5V with a small (perhaps 20mV) voltage drop across the two lines. In this condition the BUS- line actually sits at a slightly higher potential than the BUS+ line. See Figure 5. Thus, the
START BIT
The differential transceiver cell allows bus activity by other devices on the bus "+" and bus "-" I/Os when power to the cell is shut off. Therefore, this powered off condition places the transceiver outputs, BUS "+" and BUS "-", in a high impedance state. When the cell is either being powered up or down, with or without bus activity, SCR latch-up protection is provided such that this activity is not affected.
IDLE IDLE IDLE IDLE IDLE IDLE IDLE IDLE IDLE IDLE IDLE STOP BIT BIT BIT BIT BIT BIT BIT BIT BIT BIT BIT 1 2 3 4 5 6 7 8 9 10 11 7 BIT
DIFFERENTIAL BUS SCK XMIT
0
1
2
3
4
5
6
1
2 6 6
3 5 5
4 4 4
5 3 3
6 2 2
7 1 1
8 LSB LSB (4)
MSB REC MSB CONTROL (1)(3) CONTROL (2)
IDLE
NOTES: 1. 2. 3. 4. The control signal at the transmitting node. The control signal at the receiving node. There is a delay between the control pin being pulled low and the actual beginning of the start bit. If the control pin is again puled low before the end of the stop bit, then the next start bit will begin at the end of the previous stop bit. FIGURE 3. SCK, CONTROL, AND IDLE SIGNALS DURING THE SPI MODE OF OPERATION
6-89
CDP68HC68S1
Receive data is an output from the differential transceiver cell. It is the output of a differential amplifier which decodes the bus "+" and "-" I/O. When the bus "+" and "-" has been driven positive and negative respectively to a differential voltage value greater than VIDH , the output of the differential amplifier is a logic one, which is inverted and considered a 0bit from the bus. Otherwise, for level below VIDL the differential amplifier output is a logic zero, which, in turn, is inverted and considered a 1-bit from the bus. Twisted wire pair (or adjacent PC board traces) is recommended for the two differential bus lines. The BREAK input, when held at a logic zero, (low) causes the differential transmitter driver to generate a continuous logic level zero on the differential bus. This action can generate a data collision which can be either used as a break or a request for arbitration by the system. When held at logic one, (high) this input has no effect on the operation of the cell. The out of range output is normally a logic zero but goes to a logic one when the common mode voltage on both differential bus inputs exceeds a voltage value greater than VMAX or less than VMIN (see device specifications). This output is used by a latch to hold the received data at the logic level it was before the over range signal occurred. Provided on chip is a power-on reset function. The transceiver cell's reset output is held to a logic zero on power up and switches to a logic one at or before VDD rises to 4.0V. This output is used to ensure that other on-board logic has been properly initiated. During this reset time, the bus "+" and the bus "-" l/Os provide a high impedance state to the bus. Bus Speed SBlC systems typically use a bus speed of 7812.5 bits/second which is accomplished by using a 1MHz internal clock. However, no restriction on any other baud rate is designed into the chip, except its upper speed limit (see device specifications). Bus Byte Format All bytes transmitted on the bus follow the standard UART style asynchronous non-return-to zero data format consisting oft start bit (logical zero) followed by 8 data bits (LSB first), and 1 stop bit (logical one). Bus Message Format All messages transmitted on the bus consist of a number of bytes, from 1 to N, with no restriction on length. The user must be aware, however, that the longer the message length, the greater the probability of collision with messages being transmitted at random from other masters on the bus. Typical message lengths of systems now in use range from 1 to 4 bytes. The actual definition of each byte sent is left for the user to determine, i.e. the user must define the system protocol. For instance, a typical (and recommended) protocol might dictate that the first byte of each message sent be a unique address/identification byte. The first byte sent by a node (an MCU coupled with an SBl chip) might contain address information telling where (to which node[s]) the message is targeted for or where the message came from. Other possibilities would be to identify the type of message sent (e.g. an instruction or just information) or the length of the message. The remaining bytes in each message can be merely data bytes that comprise the actual message. The user can even use the last byte as a check sum so that all receiving nodes can check for errors in transmission. Messages are normally received by all nodes on the bus and may be processed by one or more micros, i.e., each MCU may decide, after receiving the first byte (address/ID byte) that this particular message is not needed for its operation. The MCU can then ignore the remainder of the message. Prioritization Since simultaneous transmission of address/ID bytes from several microcomputers is a possibility, a system of prioritization should be determined for bus arbitration. Due to the electrical characteristics of the differential data bus, each unique address/ID byte can automatically contain priority information used for bus arbitration. Merely use "lower" value ID bytes for higher priority messages. "Lower" value, in the SBlC case, means an ID byte with more zero's in its least significant locations. To further explain, since the differential bus transmits data least significant bit first and a zero overrides a 1-bit simultaneously transmitted by different nodes, an ID byte with least significant bit equal to zero will override an ID byte from a micro whose least significant bit is a one. If this does occur on-chip bus arbitration will automatically allow only one SBlC chip (with the highest priority address/ ID byte) to continue transmitting. In this case it is the micro who transmitted the 0-bit. Assuming both ID bytes contain identical LSBs (bit 0) then arbitration is carried on to the next bit (bit 1),and soon. Reflected Data Whenever a microcomputer sends data through the SBIC and onto the differential bus, it will always receive reflected data back. The reflected data is the data that was actually seen on the bus. Keep in mind that during data collisions between simultaneously transmitting micros, zeroes override ones. In addition, any noise that may have been induced on the bus may alter the resultant reflected byte.
Bus Arbitration
Bus arbitration is the attempted transmission onto the differential bus of an initial byte (preferably an address/ID byte) by one or more user microcomputers. The purpose of bus arbitration is to enable a single microcomputer to obtain sole usage of the bus for the purpose of transmitting a message. Bus arbitration is accomplished via a combination of methods which include an MCU software comparison of transmitted bytes to reflected bytes, the SBlC's collision detection circuit, and its start bit arbitration detector circuits. Collision Detection The SBlC's collision detector circuit compares the bits being sent from a user microcomputer to the reflected byte simultaneously received back from the differential bus. If the collision detector detects a difference in the data, it immediately blocks the user microcomputer's transmitted data from fur-
6-90
CDP68HC68S1
ther reaching the bus. This will happen, as stated in the "Prioritization" section, when a micro with a higher priority address/ID byte attempts "simultaneous" transmission (actually, i.e. within a time window of 1/4 bit time).That micro, with a higher priority ID byte, is obviously sending a 0-bit and its reflected byte matches the byte it is sending. Not detecting a collision, it continues to transmit its message, while the lower priority MCU is cut off from transmitting on the bus. The lower priority micro will be inhibited from transmitting on the bus until the message presently on the bus has ended (EOM = "End of Message" condition). End of Message Condition After transmitting the last byte of a message, the transmitting MCU must generate an End of Message (EOM) condition. An EOM condition is defined as a 10-bit length idle condition, i.e., the bus must remain idle (logic1) for a period of 10bit times (1280 internal clock periods). This can be done by merely creating a 10-bit delay in MCU software. Start Bit Arbitration Detection Arbitration, as discussed above, is only necessary when two or more micros attempt to transmit within 1/4 bit time (32 internal clock periods) of each other. Otherwise, once a micro begins a transmission on the differential data bus, all
ID BYTE FOR A MESSAGE USER #1 XMIT #1 REC#1 USER#2 XMIT #2 REC #2 0 USER #3 XMIT #3 0 REC #3 0 DIFFERENTIAL BUS 0 ALL CONTROL PINS ALL IDLE PINS (6) 0 0 1 0 1 (3) 0 0 0 0 1 0 0 0 1 (5) 1 0 0 0 0 0 1 (4) 0 0 0 0 1 0 0 START BIT 0 0 0 0 STOP BIT
other SBl chips sense the start bit and inhibit their microcomputers from transmitting (again, after a 32 clock period arbitration window delay). Once the arbitration detector circuit has blocked an MCU's transmission, access to the bus will be blocked until an End of Message condition. Start of Message Delay In order to properly synchronize various MCU's (which may be using different modes of operation) for impartial arbitration, each node must delay 2-bit times (256 internal clock periods) after detecting the IDLE signal drop low before transmitting, i.e., before the start bit of the next message reaches the bus. When using the SPI or Buffered SPl modes, this delay is automatically designed into the SBl chip. However, when using the SCl mode, the MCU must support this required delay. Fortunately, 68HC05 microcomputers using the SCI port will inherently experience a delay between the time that the SCl data register is loaded and the time that the start bit actually appears on the SCl port transmit pin (TxD). At a baud rate of 7812.5 bps this delay can be as long as 256 SBl chip internal clock periods. If this is so, then the user MCU does not have to worry about providing this delay.
ID BYTE FOR A DIFFERENT MESSAGE START BIT 0 (1) STOP BIT
1 0 0 0
2 0 0 1 (2) 0
3 1 1 0 1
4 0 0 0 0
5 1 1 0 1
6 0 0 1 0
7 0 0 0 0
1
2
3
4
5
6
7
0
0
1
0
0
0
1
0
0 0
0 0
1 1
0 0
0 0
0 0
1 1
0 0
0
0 (7) (6)
0
0
1
0
0
0
1
0 (7)
10 IDLE BITS
10 IDLE BITS
NOTES: 1. USER #1 is note transmitting + marking. 2. Point at which USER #2 loses bus arbitration. 3. Point at which USER #3 loses bus arbitration. 4. Point at which USER #3 loses bus arbitration. 5. This `1' bit is not overridden by the `0' bits from users 2 and 3 because both users 2 and 3 have previously been blocked from bus access due to data collisions. 6. The control pin on the transmitting node goes low earlier in both SPI modes (it is pulled low by micro). 7. The control pin remains low until the end of the last data bit of the 2 byte set when using the buffered SPI mode, but goes high at the middle of the last data bit in other modes. FIGURE 6. EXAMPLE OF THE SCI CHIP OPERATING DURING BUS ARBITRATION
6-91
CDP68HC68S1
Idle Detection An idle detector circuit is used to detect when the differential bus is in the idle condition, i.e., no user microcomputer has control of the bus and the bus is sitting at a mark condition (a logic one). The idle detector senses a received stop bit and delays for a short idle period of 10-bit times, during which the bus must remain idle. The idle output pin is then set to a logic zero (true). It is later set to a logic one by receiving a start bit. During the 10-bit time delay, if a non-idle condition such as noise is detected on the bus, the delay period counter will be restarted. Due to the 10-bit time idle delay period, once an MCU wins bus arbitration, it should send the next data byte to be transmitted within a period of 10-bit times (1280 internal clock periods). Each subsequent data byte to be sent should also not exceed the interbyte maximum of 10-bit times. If this maximum is exceeded, all SBlC chips will have detected the idle condition and now pull their idle lines low and reset their bus arbitration and collision detection circuits, thereby allowing other SBl chips with messages to send to arbitrate for the bus. Figure 6 shows the detailed operation of the serial bus interface chip during bus arbitration. This example shows the arbitration of a single byte (e.g. the address/ID byte) from three different user microcomputers. Two full arbitration cycles are shown. Break Generator A request for arbitration can be generated by a node that needs to interrupt transmission of a long data string. This can be accomplished by forcing the SBlC's IDLE pin to a logic zero; this forces a data collision (by sending 0-bits) after three data bytes have been transmitted, and the transmitting MCU is required to detect this break condition and stop transmitting. It is, however, allowed to re-arbitrate for the bus and the interrupting mode may not generate a second break condition if it loses arbitration.
SPI OR SCI MCU SPI OR SCI MCU SPI OR SCI MCU SPI OR SCI MCU 13K SPI OR SCI BUS120 SBIC BUS+ 13K BUSSBIC BUS+ SPI OR SCI SBIC
MCU
MCU
NOTE: Hardware configuration for a network consisting of two microcomputers. Notice that the pullup resistor is connected to the BUS- pin and the pulldown to BUS+. FIGURE 7A.
13K 120 13K +VDD BUS- BUS+ SBIC
120
BUS- BUS+ SBIC
BUS- BUS+ SBIC
BUS- BUS+
NOTE: Hardware configuration for a network consisting of 3 or more MCU's. Notice that the bus utilizes no more than 1 set of 13K bias resistors and no more than two 120 termination resistors. FIGURE 7B. FIGURE 7. HARDWARE CONFIGURATION FOR A NETWORK OF MICROCOMPUTERS
Using the CDP68HC68S1
Following are some hardware and software recommendations for using CDP68HC68S1 Serial Bus Interface Chip. Requirements may vary depending upon the user's system configuration.
Software (General)
Although each user's protocol may vary, the following general procedure should be followed when using the SBl chip in any mode: When a microcomputer is preparing to transmit a message it should monitor the SBlC's IDLE pin and wait for it to go low (logic zero) indicating the bus is idle. Then the MCU attempts to transmit the first byte (preferably an Address/ID byte). If no other MCUs are transmitting at this time, or if this MCU has the highest priority ID byte, the SBI chip's collision detector circuit will permit transmission. The microcomputer must then confirm transmission by reading the byte reflected back from the bus. If this byte matches the byte transmitted then the MCU has gained control of the bus and may continue to transmit the remainder of the message (if any). If the reflected byte does not match the ID byte sent then the MCU has not gained control of the bus and may not presently transmit. It should, however, check the reflected ID byte to see if the incoming message (i.e. the message from
Hardware (General)
The differential bus lines (BUS+ and BUS-) must be terminated with external resistors as shown in Figure 4. This applies, however, only to one node (an MCU/SBlC pair) along the bus. Since all SBl chips are wired in parallel across the network bus, there is no need for additional 13K bias resistors at each node. The 120 termination resistors should, however, be present at two nodes if the network does indeed contain two or more nodes. The 120 resistor provides the voltage drop across which the SBl chip senses logic zero and logic 1-bits. If two nodes each utilize 120 termination resistors as shown in Figure 7A, the effective resistance across the BUS+ and BUS- pins drop to 60 total (due to the parallel wiring method). Any less resistance would not provide an ample voltage drop for the receiver cell op amp to sense. Following these guidelines, typical systems might look like those shown in Figure 7.
6-92
CDP68HC68S1
(START) YES ANY MESSAGES TO TRANSMIT? NO IS IDLE LOW? NO NO ANY MSG ID RECEIVED?
YES = ATTEMPT TO WIN BUS ARBITRATION
YES = REC. A MSG
NO TRANSMIT THE MSG ID BYTE. IS THIS MESSAGE OF INTEREST TO US? YES
NO
HAS THE MSG ID BEEN RECEIVED FROM THE BUS? YES DOES THE REC'D MSG ID EQUAL THE TRANSMITTED MSG ID? NO = LOST
SAVE THE RECEIVED BYTE.
YES HAS THE NEXT BYTE BEEN RECEIVED YET? NO NO IS IDLE LOW?
YES = WON BUS ARB. ARE THERE ANY MORE MESSAGE BYTES TO TRANSMIT? NO
YES = SEND REST OF MESSAGE
YES
TRANSMIT THE NEXT MSG ID BYTE.
PROCESS THE MESSAGE.
HAS THE BYTE BEEN REC'D FROM THE BUS? YES YES DOES THE REC'D BYTE EQUAL THE TRANSMITTED BYTE?
NO
"TRANSMIT" AN END OF MESSAGE CONDITION.
NO
ABORT THIS MESSAGE TRANSMISSION DUE TO A COLLISION.
FIGURE 8. GENERAL MESSAGE PROCESSING.
the arbitration-winning MCU) is of any interest. If so, it should save the incoming message (the length of which may be specified in the ID byte) and then wait for the IDLE line to go high before re-attempting transmission (if still desired). The flowchart in Figure 8 reflects this procedure.
required in order to always be able to receive messages from other microcomputers on the bus, which can happen at random. For the SCl mode, the SBl chip's MODE pin must be set to1 and the CS pin to 1.
The SCl Mode, Hardware
In the SCl mode, the TxD and RxD pins on the user microcomputer must be connected to the XMlT and REC pins on the SBlC chip, respectively, as shown in Figure 9. The MCU's SCl port should be configured for the same baud rate and character format as that used by the bus interface (i.e. 1 start bit, 8 data bits and 1 stop bit). The start and stop bits are used to synchronize the data, a byte transfers between the user microcomputer and the SBl chip. When using the SCl mode, the SBl chip should always be properly mode and chip selected. This can be accomplished by either a user microcomputer output signal or by permanent wiring. This is
SCI Mode, Software
The procedure to follow for transmitting/receiving in the SCI mode is basically identical to that stated in the "Using the CDP68HC68S1-Software" section above, with the following exception: Start of Message Delay Transmitting a byte via the 68HC05 SCl port basically requires loading the byte into the MCU's SCl data register (once the SCI port is initialized). However, after the SBlC's IDLE pin drops low, the user may have to create a delay before transmitting the FIRST byte of a message; this necessary 2-bit time (256 internal clock periods) delay is called the Start of Message (SOM)
6-93
CDP68HC68S1
delay. Fortunately, SCl ports exhibit an inherent delay between the loading of the transmit data buffer and the actual beginning of the start bit appearing on the TXD pin. This delay, at 7812.5 Baud, can be as long as 256 SBl chip internal clock periods and can be used to synchronize SCl users with SPI and Buffered SPI users to ensure impartial bus arbitration. The delay for a particular microcomputer must be determined by the user. If this inherent delay is less than 256 clock periods, then the user must delay the loading of the first byte enough to ensure that the total delay including the inherent delay of the SCl port is 256 clock periods.
MCU TxD RxD PAO SBIC XMIT BUS+ REC IDLE MODE +VDD CS BUS-
Framing Errors While in the SCl mode, the SBI chip is capable of detecting incoming framing errors. It will do this even though the incoming signal is also echoed to the user microcomputer, which should also detect the framing error via its' UART. When a framing error is detected by the SBl chip, the generation of the SCK pulses is terminated until and End Of Message is detected.
The SPI Mode Hardware
The Master Out Slave In, (MOSl), and Master In Slave Out, (MISO), pins on the user microcomputer are connected to the REC and XMlT pins of the SBl chip, respectively, as shown in Figure 10. The SCK pins on the user microcomputer and the SBl chip are connected together. Synchronization of data transferred between the user microcomputer and the SBl chip is done by using the SCK signal provided by the SBl chip. In the SPl mode of operation the SBl chip should always be properly mode selected. This may be accomplished either by a user microcomputer output signal or by permanent wiring in order to guarantee that the SBl chip will always be able to receive messages from other microcomputers on the bus, which may happen at random. To select the SPl mode, set the MODE pin to a logic l and the CS pin to a logic 0.
DIFFERENTIAL BUS
FIGURE 9. USING THE SCI MODE
Monitoring the IDLE Pin The user microcomputer must monitor the IDLE pin on the SBlC chip in order to determine when a message ends, when the next received byte is a Msg ID byte, and when to attempt arbitration if the user microcomputer has a message to transmit. The user microcomputer must be able to both detect when the IDLE signal goes from high to low and sense at other times whether it is either high or low. Detecting the change from high to low is necessary in order to know exactly when the bus goes idle. An MCU can then begin bus arbitration by attempting to transmit. Being able to sense the level of IDLE is necessary in order to be able to start transmitting a message sometime after IDLE has gone low but no other user on the bus has had a message to transmit for a length of time. Instead of polling the IDLE pin via an MCU input pin, the user may wish to conserve CPU time by using interrupts to monitor bus activity. The user microcomputer's external interrupt pin (IRQ) can be used to edge detect the IDLE pin for high to low transitions. Using 68HC05 SCl Port Flags During message reception, the 68HC05 SCl port receive data register full flag (RDRF), and optionally its associated interrupt, can be used by the user microcomputer to determine when to unload the next received byte. The user may wish to ignore the RDRF flag and disable the RDRF interrupt during reception of an unwanted message. In this case the user can merely wait for the IDLE pin to go low before attempting any further actions. The normally available transmit data register empty flag (TDRE) can be used to determine when to load the next byte to be transmitted onto the bus. If there are no more bytes to be transmitted, then consider the last message as having been transmitted, and generate an End Of Message (EOM) (i.e. transmit a logic 1 for 10 contiguous bit times by creating a software delay).
MCU MISO MOSI SCK SS PAO PA1 VSS
SBIC XMIT BUS+ REC BUSSCK IDLE CONTROL MODE +VDD CS VSS
DIFFERENTIAL BUS
FIGURE 10. USING THE SPI MODE
The user microcomputer should configure its SPl port for slave mode operation with SCK positive polarity and data transfer on SCK leading edge (i.e. CPOL = 0, CPHA = 1, for 68HC05 microcomputers). 8-bit data transfers between the user microcomputer and the SBl chip occur at differential bus transfer speed. In the SPI mode, the user microcomputer operates in the slave mode and the SBl chip operates as the master. The SS pin on the user microcomputer must be wired low or forced low whenever the SBl chip has incoming data. It may be useful to connect the CONTROL pin of the SBl chip to the Slave Select (SS) pin of the 68HC05 microcomputer. The SBl chip will then control the user microcomputer's SPI port. The user microcomputer can request transmission of data onto the bus by the SBl chip by loading data into its SPl data register and then pulling the SBlC's CONTROL pin low (for at least 1s). However, it must do so before the SBl chip has begun to receive data from another MCU.
6-94
CDP68HC68S1 SPI Mode, Software
The SPl mode is similar to SCl mode in that the user microcomputer sends/receives data to/from the SBl chip 1 byte at a time. In the SPI mode, however, the user microcomputer must reverse the bit order of transmitted and received bytes. When transmitting a message, each bit of a transmitted byte is simultaneously transmitted onto the bus and a reflected bit is simultaneously received from the bus. Monitor and Control of the CONTROL Line In the SPl mode, the user microcomputer monitors the CONTROL pin on the SBl chip in order to determine if the SBlC is ready to accept a transmit request. Actually, a data collision may still occur and the user microcomputer must always be ready to handle it. The CONTROL signal is normally high and goes low when data is on the bus or when pulled low by the user microcomputer. After being pulled low by the user microcomputer, which signals a request to begin the transmission data, the CONTROL signal will latch low and stay low until the middle of the last data bit has been transmitted and appears on the bus. The CONTROL signal will also go low at the beginning of the first data bit, when received from the bus. It will then go high at the middle of the last data bit. When the SBl chip begins to receive a byte of data from the bus and the user microcomputer has not pulled the SBlC's CONTROL line low, the SBl chip will pull CONTROL low and start generating the SCK clock signal. As each data bit is received it is clocked out of the SBl chip and into the user microcomputer. Any data in the user microcomputer's SPl data register will be transferred out and into the SBl chip. The CONTROL signal will go high at the midpoint of the eighth data bit. This will allow the user microcomputer to have enough time to review the just received SPl data and reload it, if further data is needed to be transmitted. However, it must again pull the CONTROL pin low to signal he SBl chip that it should begin transmitting. As a slave to he SBl chip, the user microcomputer must be able to and le the incoming data on the SPl port without affecting its other software routine functions. Detecting IDLE via a User Microcomputer External Interrupt The user microprocessor's external interrupt should be set to edge detect IDLE for falling transitions, i.e. EOM detection. If possible, detect CONTROL for rising transitions, for byte transmission/reception complete detection. Use of Internal User Microcomputer Flags and Interrupts The normally available SPl finished flag (SPlF) and optionally its associated interrupt may be used by the user microcomputer to know when a byte transmission/reception of is complete. The user microcomputer should be ready to handle the Write Collision, WCOL, error flag. The WCOL flag is set when a collision is detected in the SPl port. This will occur when the user microcomputer tries to load a byte into the SPI data register after the SBl chip has already begun to load data into the SPl port. Sending Messages to Other Microcomputers on the Bus ln order to send a message to other microcomputers on the bus while in the SPI mode the user microcomputer should: 1. Monitor the IDLE pin and determine if the bus is currently busy or if a transmission may be immediately started. 2. Monitor CONTROL to determine if it is ok to load the byte to be transmitted into the user microcomputer's SPl data register. 3. Load the byte to be transmitted into the SPl data register. 4. Pull the CONTROL pin low to signal the SBl chip to start a byte transmit cycle. 5. Wait until the byte transmit cycle is completed as signaled by the SPl Finished, SPlF, flag/interrupt in the SPl port or by the CONTROL signal going high. 6. Compare the received byte with the last transmitted byte. 7. If the received byte equals the last transmitted byte, and more bytes remain to be transmitted, then continue the cycle with step #3. If there are more messages to transmit, then go to step #1. If there are no more bytes to be transmitted, then consider the message as having been transmitted, and generate an End Of Message (EOM) (i.e. delay for 10 contiguous bit times). Go to step #1. 8. If the received byte does not equal the last transmitted byte and this is the first byte of a message, then treat the received byte as the first byte of a received message (i.e. the ID byte). Attempt to retransmit the previous message after the IDLE signal has gone low again. If this happens during the transmission of a later message byte, other than the ID byte, then consider it due to either an erroneous data collision on the bus or due to noise collisions on the bus causing the message to have to be re-transmitted. Go to step #1. Framing Errors While in the SPl mode, the SBl chip is capable of detecting incoming framing errors. If one is detected, generation of the SCK pulses to the user microcomputer is terminated. The SBl chip essentially quits receiving data and starts looking for an End Of Message. Resetting of the SCK generator will occur upon receiving an EOM. Meanwhile, software must be prepared to resynchronize the micro's SPl port; this can be done by disabling and then reinitializing it. Even though the SBl chip can detect framing errors, it can not flag the user microcomputer that one has occurred. Since the previously received byte has already been transferred to the user microcomputer, the SBI chip will simply refuse to accept any further incoming data until an EOM occurs. Thus, one way that the user microcomputer may detect that the received data is valid, is via using a check sum byte imbedded within each message. Another way would be to compare the number of bytes received fora particular ID to the number expected for that ID.
Buffered SPI Mode, Hardware
The MOSl and MlSO pins on the user microcomputer should be connected to the XMlT and REC pins of the SBl chip respectively. The SCK pins on the user microcomputer and
6-95
CDP68HC68S1
the SBl chip should also be connected together, as shown in Figure 11. Synchronization of the data that is transferred between the user microcomputer and the SBl chip is done by the SCK signal which is provided by the user microcomputer. The Slave Select (SS) pin on the user microcomputer must be wired high or forced high whenever the SBl chip is selected. The user microcomputer should configure its SPl port for master mode operation, SCK low polarity, and data transfer on first edge (i.e. CPOL = 0, CPHA = 1 for 68HC05 microcomputers). The SBI chip must be chip selected either by a user microcomputer output signal or by permanent wiring of its pins. To select the Buffered SPl mode, set the MODE pin and the CS pin to logic zero. This is required in order to transfer data between the SBl chip and the user microcomputer. However, in the Buffered SPl mode, since the MCU is operating as a master and controls the SPI port, chip selection is only required during when the SPl transfers are actually occurring.
MCU MOSI MISO SCK SS PAO PA1 +VDD IDLE CONTROL MODE +VDD CS SBIC XMIT BUS+ REC BUSSCK
While it is transmitting and receiving the 2 bytes of data on the differential bus the SBl chip will not allow transfer of data to and from the user microcomputer. In fact, the SBl chip does not need to be chip selected during this time. The bus will override the user microcomputer if incoming data is received during the time when the user microcomputer is performing a data transfer, after having unloaded the previous 2 bytes. The data from the differential bus will be loaded into the SBlC buffer, while the data from the user microcomputer will be lost. The data that the user microcomputer will receive during this transfer, is undefined. The user microcomputer has no way of knowing its transfer has been aborted unless it either monitors the CONTROL signal for a rising transition or by detecting that CONTROL was not high at completion of the SPl transfer. Monitoring the Control Signal The user microcomputer should monitor the CONTROL signal on the SBl chip, in order to determine whether it is actively transmitting or receiving data. The CONTROL signal is used to determine who has access to the 2 byte buffer. During data reception or transmission to the differential bus by the SBlC its CONTROL pin is low signifying that the differential bus now has access to the SBlC and the MCU is locked out from accessing the SBlC. Then when 2 bytes of data have been received from the differential bus, the SBl chip will pull its CONTROL line high, signaling to the MCU that the MCU can now access the SBlC's 2 byte buffer. The MCU may now read the 2 bytes received and simultaneously transmit two more bytes (if desired) by performing a 2 byte transfer (a swap of data), via the MCU SPl port, with the SBlC; then the MCU pulls the SBlC's CONTROL pin low to transmit the two new bytes. The CONTROL pin will remain latched low (by the SBlC) until the two new bytes are transmitted. The user microcomputer should also monitor the IDLE signal in order to accurately know when the bus is idle or when bus arbitration is occurring, when a received message has finished, and when the next bytes to be received are the beginning bytes of a new message. Preferably, the user microcomputer's external interrupt should be set up to edge detect falling IDLE and rising CONTROL transitions. When the CONTROL pin goes high, it signals that the buffer is full and that the user microcomputer currently has access. When the IDLE pin goes low, it is signaling that the current message has been completed, and an MCU may now arbitrate for the bus. Size of Messages that can be Transmitted or Received In the Buffered SPI mode, the user microcomputer can only send messages in 2 byte multiples. Transmitting messages with an odd number of bytes, to other microcomputers on the bus, is NOT supported by the SBl chip in Buffered SPl mode. However, reception of any number of bytes is supported. In the Buffered SPl mode, the user microcomputer can receive messages of any length. For odd length messages, the user microcomputer must know when the message is finished either from the message ID byte or via the IDLE signal. Since the SBl chip will give no indication as to whether the buffer contains one or 2 bytes of information from the bus, the message length should be contained within the message data bytes.
DIFFERENTIAL BUS
FIGURE 11. USING THE BUFFERED SPI MODE
Buffered SPI Mode, Software
The principle difference between the Buffered SPI mode and the normal SPl mode is the use of a 2 byte internal buffer. Also, the Buffered SPl mode allows the user microcomputer to operate in the master mode, instead of the slave mode, which allows high speed transferring of data between the SBl chip's buffer and the user microcomputer. For typical operation, the user microcomputer loads the SBl's 2 byte buffer, at a high speed, using its SPl interface. The 68HC05's SPl Finished flag (SPlF), and optionally its associated interrupt, may be used by the user microcomputer to know when the transfer of a byte between the user microcomputer and the SBl chip is complete. Then it signals the SBl chip, by pulling its CONTROL line low, to transmit the data in the buffer onto the differential bus. The SBl chip, at a differential bus speed, then attempts to transmit the buffered data onto the bus. During this attempt, the SBl chip will receive two reflected bytes of data back from the bus, store them in the buffer and then disable the buffer from receiving further data from the differential bus until this received data is later unloaded by the user microcomputer at high SPl transfer speeds. The MCU should also, at this time, simultaneously load the next 2 bytes of data to be transmitted into the buffer.
6-96
CDP68HC68S1
When a single byte is received from the bus, followed by a bus idle condition, the SBl chip will, as it normally does when the buffer has received 2 bytes, set the CONTROL signal high. It will then relinquish control of the buffer for data transferral via the user microcomputer, and restrict access to the buffer from incoming bus data until the 2 byte data transfer has been completed. If only 1 byte is received from the bus, the user microcomputer will receive it first when performing the 2 byte data transfer. The second byte received by the user microcomputer, during this transfer, is undefined. A 2 byte transfer is still required in order to return control of the buffer back to the SBl chip, to gather further incoming data from the bus. Power On/Reset The SBI chip is reset internally, at power on. After reset, the CONTROL pin is set high and IDLE is set low. The buffer access is set as though 2 bytes have just been received from the bus. A 2 byte transfer must be performed, via the user microcomputer, in order to initalize the SBl chip for general operation. Sending Messages to Other Microcomputers on the Bus In order to send a message to other microcomputers on the bus, while in the Buffered SPl mode, the user microcomputer should: 1. Monitor the SBlC CONTROL pin to know when it is ok to perform the 2 byte transfer between the user microcomputer and the SBl chip. 2. Perform the 2 byte transfer between the user microcomputer and the SBl chip for the first 2 bytes of the message. 3. Pull CONTROL low to tell the SBI chip to start a 2 byte bus transmit cycle. 4. Wait until CONTROL goes high again indicating that the 2 byte transmit cycle has completed. 5. Perform another 2 byte transfer between the user microcomputer and the SBl chip, thus giving it the next 2 bytes to be transmitted and giving the user microcomputer the 2 bytes just received. 6. Compare the just received 2 bytes with the 2 bytes which were attempted to be transmitted. 7. If the received and last transmitted bytes are equal and more bytes remain to be sent, then continue the cycle with step #3. 8. If the received and last transmitted 2 bytes are unequal, then restart with step #2. Creating an EOM after a Message Transmission There must be at least a 10-bit interval of bus idle between the stop bit of the last byte of one message and the detection of the start bit of the first byte of the next message. This can be implemented by either: 1. Including a 10-bit interval time out, via using a timer or software loop. 2. The user microprocessor can simply wait until it senses IDLE going low. Receiving Messages from Other Microcomputers on the Bus If the user microcomputer loses arbitration, or if it has no message to transmit and another microcomputer begins to send its message onto the bus, the SBI chip will begin to receive a message from the bus. The SBlC CONTROL pin will go low at the beginning of the first data bit that is received from the bus. It will go high either whenever 2 bytes have been received, or when 1 byte has been received followed by the bus going idle (i.e. when IDLE goes low). The transition of CONTROL from low to high indicates that the SBI chip has 2 bytes in its internal buffer for the user microcomputer to retrieve. Whether the SBl chip has received either 1 or 2 bytes, the user microcomputer must perform a 2 byte transfer in order to return control of the buffer back to the SBI chip. The user microcomputer must detect CONTROL going high and transfer the 16-bits from the SBl chip before the beginning of the first data bit of the next message or else the bus will be locked out of accessing the buffer until after both the next 16-bit transfer is complete and IDLE goes low. Thus, if there was further incoming data and this did occur, some of the incoming data may be lost. Framing Errors While in the Buffered SPl mode, the SBl chip is capable of detecting incoming framing errors, however it is unable to flag this to the user microcomputer. When the SBl chip detectsaframing error, anyfu rther loading of the SBl chip's internal buffer is terminated. The SBI chip essentially quits receiving data and starts looking for an End Of Message. Resetting of the framing error will occur upon receiving an EOM. Even though the SBl chip can detect framing errors, it can not flag the user microcomputer that one has occurred. Since the previously received byte has already been loaded into the SBI chip's buffer, the user microcomputer must determine whether this data is valid. If a framing error occurs during the first byte of a 2 byte reception, access to the buffer will be restricted from the user microcomputer until and EOM occurs. lf a framing error occurs during the second byte of a 2 byte reception, the user microcomputer will be given access to the buffer. However, even if the user microcomputer unloads the buffer, the SBI chip will not load any further data into the buffer until an EOM occurs. Basically, when a framing error occurs, no further data is read from the bus and buffer access is given to the user microcomputer either immediately or upon an EOM. One way that the user microcomputer may detect that the received data is valid, is by using a check sum byte imbedded within each message. Another way would be to compare the number of bytes received for a particular lD to the number expected for that ID.
References
Portions of the information contained in this document were taken and condensed from Chrysler Corporation's "CCD USER'S MANUAL" issued April 15,1987.
6-97


▲Up To Search▲   

 
Price & Availability of CDP68HC68S1

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X